FAQs

What do we mean by "biological agent"?
In the UAB, the concept of biological agent goes a little beyond what is defined in article 2 of RD 664/1997. Therefore, we consider a biological agent as any organism, including those which have been genetically modified, biotoxin, protein (ex. prion), allergen, cell cultures and endoparasite, which may be able to provoke any infection, allergy or toxicity in humans, animals, plants or harmful effects to the environment.

What do we mean by confined activities with biological agents?
It is an operation in which genetically modified or pathogenic organisms are cultured, stored, transported, destroyed, disposed or used in any other way, and for which specific containment measures are used to limit their contact with, and to provide a high level of safety for, the general population and the environment. An operation can take place in a laboratory (research, diagnosis), an animal facility (small and / or large animals), a greenhouse or a large-scale process facility (production).

What is a Genetically Modified Organism (GMO)?
Law 9/2003 defines GMO as "any organism, with the exception of human beings, which has been modified, through specific techniques of genetic manipulation, a modification of its genetic load (genome)". It is therefore induced modifications, different from those that occur naturally in mating, recombination or in any other biological process of transfer of genetic material. The modification may consist of a modification of the expression of their genes, deletions or partial losses thereof, or the incorporation of genetic material from other species or varieties.

What is self-cloning?
According to Directive 2009/41/EC (Annex II Part A), self-cloning in risk group 1 or multicellular organisms (excluding germ cells of human origin) consists in "the removal of nucleic acid sequences from a cell of an organism, which may or may not be followed by reinsertion of all or part of that nucleic acid (or a synthetic equivalent), with or without prior enzymatic or mechanical steps, into cells of the same species or into cells of the same species or of phylogenetically closely related species which can exchange genetic material by natural physiological processes where the resulting micro-organism is unlikely to cause disease to humans, animals or plants.
Self-cloning may include the use of recombinant vectors with an extended history of safe use in the particular micro-organisms.

Are the risk/hazard group and the biosafety/biocontainment level synonymous?
Previous versions of the WHO "Laboratory Biosafety Manual" described the classification of biological agents and laboratories in terms of risk/hazard groups and biosafety/containment levels. While this may be a logical starting point for the handling and containment of biological agents, it has led to the misconception that the risk group of a biological agent directly corresponds to the biosafety level of a laboratory. In fact, the actual risk of a given scenario is influenced not only by the agent being handled, but also by the procedure being performed and the competency of the laboratory personnel engaging in the activity.

Who can be a Principal Investigator (PI) on an IBC protocol?
The PI is a member of the academic staff or senior research who bears responsibility for the intellectual leadership of a project. The PI accepts overall responsibility for directing the research, the financial oversight of the award's funding, as well as compliance with relevant University policies and sponsor terms and conditions of the award.

Are an experimental procedure and a research project synonymous?
No, although they may match. A project may have one or several experimental procedures (work with animals, plants, microorganisms, cell lines, arthropods, samples, large scale, etc.) with different biosafety levels that require facilities and work practices clearly differentiated.

My research involves work with E.coli K-12, plasmids, and Saccharomyces spp. Is this research required to be registered with the IBC?
Yes. It is dependent upon the genetic material that is being manipulated as to whether or not the work just needs to be registered or if the work needs to go to the IBC for full approval. Submit an IBC Registration Form.

Can I just submit a research summary via e-mail to be reviewed and approved?
No. There is an electronic application form for IBC registration. Contact the Biosafety Officer (tel. 8049) for assistance with access to the web-based application.

When does an IBC-UAB protocol approval expire?
An approved protocol of BSL1 or BSL2 expire after 3 years from its initial approval date. If the protocol require a BSL3 the validity is for one year.

How do I amend my biosafety protocol to reflect updates to lab personnel?
A formal amendment to a biosafety protocol for the addition or deletion of individuals from the protocol personnel list is not necessary as it is for grants and research changes. Simply send an email to comite.bioseguretat@uab.cat with your updated list of personnel. The IBC-UAB will note this change and file with your currently approved protocol.

Why do we have to keep our laboratory doors closed?
There are numerous reasons that doors to labs should be closed:
• Work at all biosafety levels requires limited or restricted access to the lab when work is in progress.
• Some laboratories are designed to be under negative pressure to surrounding rooms and corridors (air flows into the lab) and building ventilation systems are balanced when doors and windows are closed. Keeping doors open causes the pressure differential to drop and makes the directional airflow negligible and easily disturbed.
• Closed doors help contain chemical vapors and aerosolized infectious agents and confine flames and smoke.
• Closed doors help deter thieves.

Why is hand washing with soap and water better than using an alcohol-based disinfectant?
CDC (Centers for Disease Control and Prevention) recommends washing hands with soap and water whenever possible because handwashing reduces the amounts of all types of germs and chemicals on hands. But if soap and water are not available, using a hand sanitizer with at least 60% alcohol can help you avoid getting sick and spreading germs to others. That said, it can be added that:
-Soap and water are more effective than hand sanitizers at removing certain kinds of germs, like Cryptosporidium, norovirus, and Clostridium difficile. Although alcohol-based hand sanitizers can inactivate many types of microbes very effectively when used correctly (ex. coronavirus), people may not use a large enough volume of the sanitizers or may wipe it off before it has dried.
-Many studies show that hand sanitizers work well in clinical settings like hospitals, where hands come into contact with germs but generally are not heavily soiled or greasy. Hands may become very greasy or soiled in community settings, such as after people handle food, play sports, work in the garden, or go camping or fishing. When hands are heavily soiled or greasy, hand sanitizers may not work well. 
-Hand sanitizers without 60-95% alcohol 1) may not work equally well for many types of germs; and 2) merely reduce the growth of germs rather than kill them outright.
-The presence of alcohol in the disinfectant solution and applied with high frequency can lead to certain problems for certain people with particularly sensitive skin.
Hand hygiene is the most efficient and cheapest way to limit the spread of disease.

Doesn’t the UV light in my BSC disinfect everything?
The international standards on laminar flow cabinets (EN12469: 2000, NSF 49) explicitly discourage the use or even the installation of UV lights in BSCs. In order to be effective, UV lamps must be cleaned weekly to remove dirt and dust and should be checked periodically (approximately every 6 months) with a meter to ensure the appropriate intensity of UV light is being emitted for germicidal activity. UV lights must be turned off when the room is occupied to protect eyes and skin from UV exposure.

How often should our biosafety cabinet (BSC) be certified?
BSCs must be certified at the time of installation and annually thereafter. They should also be certified anytime they have been moved and after some repairs (HEPA filter replaced, maintenance to internal parts).

How often should HEPA filter be replaced?
The durability of a HEPA filter will depend on the quality of the filtered air, the time of use and the characteristics of the processes that are carried out and that may affect the air quality or directly the state of the filter.
It is expected that, with the passage of time, the filter will decrease its flow rate, to the point at which it is considered saturated. Statistical studies show an average duration time for HEPA filters of 5 to 7 years. In air environments with very low concentration of particles and procedures with low release of particles, these times can be increased.
The need to replace the HEPA filter is evidenced by the results of the periodic qualification tests that will determine its status. If the filter does not pass the saturation, flow and absence of leak tests, it must be replaced since no type of repair can be done.

Why aren’t Bunsen burners or open flames permitted inside the BSC?
The use of open flames, flammable gases, and flammable liquids inside a BSC:
• Disrupts the air flow, compromising protection of both the worker and the work.
• Causes excessive heat buildup which may damage HEPA filters and/or melt the adhesive holding the filter together, thus compromising the cabinet’s integrity
• Presents a potential fire or explosion hazard. Electrical components such as the BSC fan motor, lights and electrical outlets are not designed to operate in flammable atmospheres, where a flash fire could be ignited by a spark. A majority of BSCs, recirculate 30-70% of the air in the cabinet through a HEPA filter; gas leaking in the cabinet from a faulty connection or burner can quickly build to explosive levels due to this recirculation process.
• Cabinet manufacturers will assume no liability in the event of fire, explosion or worker exposure due to the use of a flammable gas in the cabinet.
Alternatives to Bunsen burners and open flames include:
• Alternative technology such as electric incinerators, glass bead sterilizers
• Disposable loops, spreaders, and other instruments
• Pre-sterilized packs of instruments such as tweezers, scissors and scalpels
If it is deemed absolutely necessary for the work being done, a small alcohol burner containing only enough alcohol for one day’s work, or a touch-plate microburner, providing a flame on demand may be used.
 

What plastics are autoclavable?
Only polypropylene and polycarbonates. Polyethylene is not autoclavable.

How long should I autoclave the liquids?
Generally, the liquid volume determines the length of sterilization needed. A comparative example between half-full bottles with vented caps shows that a minimum of 30 minutes of sterilization time is required for 250 mL, 45 minutes for 1000 mL and 55 minutes for 2000 mL.
Other factors to consider are the viscosity of your solution, the material of your container (glass, plastic, or metal), the packing density (separate bottles to allow steam to surround each bottle), and the location in the autoclave (close to the wall vs center of unit, over the drain).
Never autoclave a sealed container of liquids as this may result in an explosion of superheated liquid during the cycle or when the container is opened.

Why is my liquid cycle taking so long? 
Depending on the unit, liquid cycles can take up to 30 minutes longer to run than the set sterilization time due to slow charge and slow exhaust steps.

How often should autoclave be validated?
It is necessary to evaluate the effectiveness of the autoclave, with biological indicator, at least once every 40 hours of operation, or after a repair, and record it. A negative test result may indicate the need for equipment calibration.

How is autoclave cycles validated with biological indicators?
To carry out the validation of the autoclave cycles for the treatment of biohazardous waste with a biological indicator (BI), the Biosafety Unit supplies a container, with a pre-printed identification label, which contains a vial with a suspension of Geobacillus stearothermophilus spores. For more details, you can consult the procedure on the intranet.

Why is it necessary to test with biological indicator if we place autoclave tape on all items to be autoclaved?
Indicator tape does not measure/guarantee effectiveness of sterilization; only spore testing does. Use indicator tape with each load to verify it has been autoclaved.

How do I include an autoclave in the annual qualification program?
To register an autoclave in the annual qualification program you must fill in the following e-form.

I am interested in measuring the pressure and temperature of my autoclave, how can I do this?
In the Biosafety Unit, we currently have 4 temperature dataloggers and one pressure/temperature datalogger that can be reserved by groups working with autoclaves at the UAB. To request you must fill in the following e-form.

Can I attend one of the courses scheduled by the IBC if I do not work at the UAB?
In accordance with the guidelines laid down by the Training Unit, all groups of UAB staff have access to training in the areas of occupational health and safety prevention (PAS-PA-PIF). The staff of foundations, companies or institutions linked to the UAB (Esfera, Parc de Recerca, etc.) have access to the training provided that there are places available and they pay the proportional cost of the expenses associated with the training action.
 
What happens if the biosafety training requirements are not met?
Since this training is necessary to comply with the requirements of the IBC-UAB and the competent authority (labour or environment), it is of interest to your laboratory that all the research and technical personnel associated with a research project can accredit it. The lack of training of any member of the group may result in delays in a process of notification of facilities or activities involving biological agents.

What is the difference between Sterilization, Disinfection and Decontamination?
Sterilization is a process (physical or chemical) which destroys all viable, or living, forms of microorganisms.
Disinfection is a process which reduces or eliminates microorganisms in their vegetative state from a surface or space. Spores may not be killed by disinfection.
Decontamination is a process that eliminates or reduces biological agents to a safe level in terms of the transmission of disease or other adverse effects and rendering an object safe for handling.

Why should you not autoclave waste which is contaminated with hazardous chemicals?
The hazardous chemical may volatilize and cause exposures to the operator when the autoclave is opened. It can also damage it (corrosive) or contaminate it (toxic or radioactive).

Our lab needs to order a product from ATCC which requires the signature of the Biosafety Officer. How can we accomplish this?
Please send the completed ATCC forms to comite.bioseguretat@uab.cat, indicating the biological material being ordered and the code of the approved experimental procedure by the IBC-UAB, if applicable. The Biosafety Officer will verify the information provided and, if everything is correct, sign the required form and send a scanned copy to the applicant PI via campus mail.
 

What is a biological spill kit and do I need one?
Advance preparation for management of a biological spill is essential. A biological spill kit can easily be assembled using items that should already be available in the lab. A complete biological spill kit consists of:
• Dust pan & scoop or tongs for broken glass/sharps.
• Paper towels or other absorbent material.
• Concentrated household bleach.
• Several pairs of latex or nitrile gloves.
• Safety glasses.
• Biohazardous waste (autoclave) bags.
These items should be placed in a labeled box or bucket and kept in areas where biohazards are used (and kept separate from the required chemical spill kit). All labs working with infectious/potentially infectious material or recombinant DNA should have a biological spill kit assembled. Spill handling procedures should be posted in the lab and all individuals should know how to properly clean a spill. 

What type of disinfectant should I use?
When considering which disinfectant to use, you need to ensure that the disinfectant you choose is effective against the organism(s) you are trying to kill. Additionally, you should consider the surface or item that needs to be disinfected, corrosive nature or other hazards associated with the disinfectant and its ease of use. The IBC recommends a freshly-diluted (within 24 hrs) bleach solution for routine surface disinfection as bleach is effective, low cost, readily available, and may be disposed down the drain after use. If you do not wish to use bleach, choose another disinfectant and follow manufacturer’s instructions for the appropriate concentrations and contact times to be used and for disposal requirements. Please note that aqueous alcohol solutions (e.g. 70% ethanol) are not appropriate for surface decontamination as these solutions evaporate too quickly to achieve the necessary contact time (10 minutes).

What is the shelf-life of undiluted bleach?
Undiluted household bleach stored at room temperature in the original container maintains its label strength active level for approximately 6 months after the manufacturing date before starting to degrade into salt and water. The hotter the temperature the bottle is stored at, the faster the decomposition. For this reason, it is important to date your bleach containers when you receive them. You should also periodically replace the bleach in your biological spill kit to be sure that you are using the bleach at label strength which is required for use.

Will my laboratory be inspected?
Yes. The IBC-UAB is responsible for conducting regular facilities inspections where confined biological agent activities are carried out (e.g., laboratory, animal facilities, cell cultures labs, greenhouses, etc.). In addition, the laboratories are subject to inspection by state and local regulatory agencies.

How can I prepare for the biosafety inspection?
Be sure all laboratory personnel have completed required training and are familiar with policies and practices for the safe use and disposal of biological materials (e.g. human, animal, and plant pathogens, recombinant DNA, biological toxins). Inspection checklists (intranet) are aligned with legal and international standards requirements.